Heat-treatment Fiberglass Sleeving, View Fiberglass Sleeving ...

Fiberglass sleeving is often used in many different types of electrical products.  It is used to insulate from heat.  It is used to hold wires together.  It is used to cover splices.    It comes in different materials for different applications. 

 

It is important to know there are difference types of sleeving and although it says UR, it may be the wrong UR category.  There are two main categories UL Recognizes Sleeving under – Flame Retardant and Coated Electrical.  The last thing you want to do is pick the wrong one, order 100,000 feet of it, go into production only to find out 2 weeks before shipping it is UR in the wrong category.

 

 

UZIQ2.GuideInfo - Sleeving, Flame Retardant – Component

 

CONDITIONS OF ACCEPTABILITY

Consideration is to be given to the following Conditions of Acceptability when these components are employed in the end-use equipment:

1. This sleeving has not been investigated for any electrical or mechanical capabilities.

2. This sleeving has not been investigated to determine its thermal performance.

3. This sleeving has not been investigated for use in contact with sharp edges, corners, projections or burrs, or where subject to tension, compression, abrasion, repeated flexing or where exposed to ultraviolet radiation or oil contamination.

 

 

UZFT2.GuideInfo - Sleeving, Coated Electrical - Component

 

CONDITIONS OF ACCEPTABILITY

Consideration is to be given to the following Conditions of Acceptability when these components are employed in the end-use equipment:

1. Sleeving shall not be used over the maximum voltage rating.

2. Sleeving shall not be used over the maximum temperature rating.

3. The minimum wall thickness of the sleeving shall comply with the requirements of the end product.

4. Sleeving marked "Oil Resistant 60°C " or "Oil Resistant 80°C" has been investigated for intermittent or occasional contact with oil not exceeding the oil rating.

5. Sleeving marked "VW-1" has been investigated using a fine wire support in conducting the flammability test.

6. Sleeving is not acceptable for use in contact with sharp edges, corners, projections or burrs , or where subjected to tension, compression, abrasion or repeated flexing without additional testing.

7. Sleeving is not recommended for use where it is feasible to employ a standard insulated conductor (appliance wiring material) intended for the purpose.

8. Sleeving shall be used in dry and damp locations only as defined in ANSI/NFPA 70, "National Electrical Code."

 

Transition to UL 970, Commercial Displays

With more and more people using electronic displays to market and sell their wares today, UL has developed UL 970.

UL 970 consists of the combination of UL 65, Wired Cabinets and UL 962, Household and Commercial Furnishings.

The transition date for compliance to UL 970 is February 20, 2022.

Intertek has put together a Facts Sheet that explains the transition to the new requirements.

Check the link here: DOWNLDOWNLOAD THE FACT SHEETOAD THE FACT SHEET                 

Whether you have an existing product or a new design, we are able to assist you in meeting the new standard.

Compliance Tip: Designating the Correct Driver Can Save Time and Money

 

LED Drivers have always been in the Recognized Component program at UL. One problem is being able to use multiple suppliers of Drivers without having temperature testing being repeated. UL was proactive in this regard and has introduced the TL program for Drivers. Get your Luminaire Listed with a TL rated Driver and get alternate Drivers added with no additional temperature testing. Your UL descriptive report still needs to be updated, but getting out of temperature testing speeds up the process. Talk to your suppliers or look in UL’s Category “FKSZ2” to find Drivers with a TL rating. Pick the hottest one your Luminaire can handle and adding lower rated TL Drivers is paperwork.